9 Details on Servo Parameters
9 - 106
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
• Clears the multi-rotation counter of the absolute encoder. Clear is executed by the writing of
6A646165 hex
to this object.
• Set the value to this object while the motor stops and it is in Servo OFF state.
• Clears the Encoder Communications Error Count. Clear is executed by the writing of
1
to this object.
• Gives the status of the multi-rotation counter of the absolute encoder and Encoder Communications
Error Count Clear.
Description of Set Values
Subindex F1 hex: Absolute Encoder Setup
Subindex F2 hex: Encoder Communications Error Count Clear
Subindex FF hex: Clear Status
Set value
Description
Bit 0
Status of Absolute Encoder Setup
0
Clear is not executed or completed
1
Clear in execution
Bit 1
Status of Encoder Communications Error Count Clear
0
Clear is not executed or completed
1
Clear in execution
Содержание R88D-1SN ECT Series
Страница 544: ...7 Applied Functions 7 52 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 560: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 700: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 969: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 972: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...
Страница 973: ......