Installing the Hardware
Step 3: Configuring the Voice Boards
Octel 50 Installation Guide
3-6
IRQ6 = disk drive
IRQ7 = LPT1
Setting the board’s default line state–The fourth jumper on SW1 determines whether
the lines connected to the voice board return a ring-no-answer signal or a busy signal
when the Octel 50 system is not running. Make sure this jumper is always on to indicate
that the lines should return a busy when the Octel 50 system is not running.
Configuring for multiple boards–If you are installing multiple Dialogic boards, remove
the JP7 jumper clip on all but the first board. If you are using a single board, leave the JP7
jumper clip installed.
Configuring Rhetorex Boards
Rhetorex 432, 4132 and 4108 boards are supported for existing systems in which they
are already installed.
All Rhetorex boards are configured the same way for Octel 50. All Rhetorex boards are
factory-set to a default address of 300 hex. If you are only installing one voice board,
leave the port address at the factory default unless it conflicts with the address of another
system component. If you are using multiple Rhetorex boards, you must assign a unique
port address to each board. Check with your PC manual to determine an available port
address.
The following figure illustrates the default settings for the 432 board. On the 432 board,
the EJ1 jumper block sets the port address.
The following figure illustrates the default settings for the 4132 and 4108 boards. On the
432 board, the W1 jumper block sets the port address.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...