Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-72
When/How to Use
When this code is used, the caller hears the Personal
Greeting prompt.
The Octel 50 system automatically sets this parameter when
the Integrator utility is run. You should not need to change
it.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual number.
Related Parameters/Features
The Location of Inband Signaling Code parameter specifies
where this code is located in an incoming inband string.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
32
Default
Blank
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Inband Code for Go to Voice Mail Parameters - #134
Location of
Mailbox Number
This parameter specifies which digit in the string for Go to
Voice Mail is the first digit in the mailbox number that follows
the code.
When/How to Use
The setting of this parameter depends on whether the count
starts from the beginning or the end of the string.
Related Parameters/Features
The Location of Mailbox Number and the Start at the End of
String parameters work together. For example, if the
incoming string is 9*1123 and the mailbox number is 123,
the Number of DID Digits to use is 6, the DID Code is 9*1,
the Location of Inband Signaling Code is 1, and, if Start at
End of String is set to Yes, the Location of Mailbox Number
is 3. If Start at End of String is set to No, the Location of
Mailbox Number is set to 4.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
1
Max
99
Default
1
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Inband Code for Go to Voice Mail Parameters - #135
Start at End of
String
This parameter specifies whether the system starts at the
end of the inband signaling string for Go to Voice Mail when
counting digits to locate the start of the mailbox number.
When/How to Use
Enable this parameter if variable-length strings are used.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...