Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-86
Related Parameters/Features
The Location of Inband Signaling Code parameter specifies
where this code is located in an incoming inband string.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
32
Default
Blank
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Inband Code for Go to Automated Attendant and Get Mailbox - #161
Total Length of
String
This parameter specifies the number of characters and
digits in the Code for Go to Automated Attendant and Get
Mailbox string.
When/How to Use
Calculate the Total Length of String by counting the number
of characters and digits that are sent in the Code for Go to
Automated Attendant and Get Mailbox string. For example,
if the code is $ and the mailbox number is 1000, the string is
$1000. In this case, the Total Length of String is 5.
If this parameter is set to 0, the system does not test the
string length.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual number.
Related Parameters/Features
The length of the Inband Code String and the Number of
Digits in a Mailbox parameters determine the setting of the
Total Length of String parameter.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
99
Default
0
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
No
Inband Code Default
The Inband Code Default parameters configure the Octel 50 system to properly receive
and interpret the inband information sent from the switch.
When the Integrator utility is run, the Octel 50 system enters default settings for the codes
required by the switch. These settings are determined based on default settings for the
switch. If you or the manufacturer modify the switch programming or features, integration
may be affected. If this occurs, call a technical support representative.
Inband Code Default - #162
Location of
Mailbox Number
This parameter specifies which digit in the default inband
signaling string is the first digit in the mailbox number that
follows the code.
When/How to Use
The setting of this parameter depends on whether the count
starts from the beginning or the end of the string.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...