Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-90
If Set Too Low
Noise spikes on the line could cause disconnect. Set this
parameter to 0 to disable it.
A low setting may also cause call ghosting on the ports.
Min
0
Max
30000
Default
30
Requires
Restart
Yes
Switch-
Dependent
Yes
Set by
Integrator
Yes
Hangup Detection Parameters - #169
Maximum
Silence Before
Hanging Up
(MAXSIL)
This parameter specifies the amount of time, in 10
millisecond units, during message recording that the Octel
50 system records silence before it determines the caller
has hung up and drops the line. MAXSIL prevents the Octel
50 system from recording silence when a caller has hung up
during a record session.
When/How to Use
This parameter is used for switches that do not use positive
disconnects or dial tones to indicate disconnects.
For most Octel 50 systems, the default value should be
sufficient.
Related Parameters/Features
Set this parameter to a value less than 1000 if using AMIS
messaging.
Set this parameter to a value greater than 0 if using
HANGUPSTR.
If Set Too High
The Octel 50 system records silence. Also, switches could
detect a port as available and mistakenly pass incoming
calls to a port on which Octel 50 system is recording silence
(missed disconnect). In this case, a new caller would
append to the previous recording.
If Set Too Low
Callers could be cut off during recording due to natural
pauses when they speak.
Min
0
Max
30000
Default
600
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
No
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...