Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-47
When/How to Use
For most Octel 50 systems, the default value is sufficient. If
the Octel 50 system experiences heavy traffic, increase this
value.
Related Parameters/Features
None.
If Set Too High
The higher the setting, the more times the Octel 50 system
attempts to send the page.
If Set Too Low
If the Octel 50 system cannot access the busy paging
system at the first attempt, the page is not voiced.
Min
0
Max
9
Default
3
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Intercom Paging Parameters - #90
Max. Number of
Retries in Paging
(Intercom
Redirect)
This parameter specifies the number of times the Octel 50
system allows a caller to retry a page. When the caller
reaches the maximum number of retries, the Octel 50
system prompts the caller to try another extension, leave a
message, or disconnect.
When/How to Use
When setting this parameter, consider the following:
•
If Repeat Intercom Paging Phrase is enabled, the
Octel 50 system voices the paging announcement
twice for each paging attempt before prompting the
caller to try another extension, leave a message,
retry the page, or disconnect. Note that the Octel 50
system prompts callers to try the page again only if
Max. Number of Retries in Paging (Intercom
Redirect) is set greater than 0.
•
If the subscriber’s mailbox is enabled for automatic
paging, the Octel 50 system immediately pages the
subscriber when the extension is not answered,
before prompting the caller to try another extension,
leave a message, retry the page (if this parameter is
greater than 0), or disconnect.
Related Parameters/Features
The Paging Wait Time (Intercom Redirect) parameter
determines the amount of time the Octel 50 system waits
after paging a subscriber allowing the caller to retry the
page.
If Set Too High
The higher the setting, the more times the intercom paging
announcement is voiced.
If Set Too Low
Does not affect Octel 50 system performance.
Min
0
Max
9
Default
3
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...