Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-75
Min
1
Max
99
Default
1
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Inband Code for Go to Immediate Record Parameters - #139
Start at End of
String
This parameter specifies whether the system starts at the
end of the inband signaling string for Go to Immediate
Record when counting digits to locate the start of the
mailbox number.
When/How to Use
Enable this parameter if variable-length strings are used.
Related Parameters/Features
The Location of Mailbox Number and the Start at the End of
String parameters work together. For example, if the
incoming string is 9*1123 and the mailbox number is 123,
the Number of DID Digits to use is 6, the DID Code is 9*1,
the Location of Inband Signaling Code is 1, and, if Start at
End of String is set to Yes, the Location of Mailbox Number
is 3. If Start at End of String is set to No, the Location of
Mailbox Number is set to 4.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
No
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Inband Code for Go to Immediate Record Parameters - #140
Total Length of
String
This parameter specifies the number of characters and
digits in the Code for Go to Immediate Record string.
When/How to Use
Calculate the Total Length of String by counting the number
of characters and digits that are sent in the Code for Go to
Immediate Record string. For example, if the code is $ and
the mailbox number is 1000, the string is $1000. In this
case, the Total Length of String is 5.
If this parameter is set to 0, the system does not test the
string length.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual number.
Related Parameters/Features
The length of the Inband Code String and the Number of
Digits in a Mailbox parameters determine the setting of the
Total Length of String parameter.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
99
Default
0
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
No
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...