Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-93
If Set Too Low
The minimum of 1 should be sufficient for most Octel 50
system ports.
Min
–
Max
–
Default
11111111
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
No
Channel Specific Parameters - #174
Go OFF Hook
when Port
Disabled
(OFFHDIS)
This parameter determines whether the Octel 50 system
takes a port off hook when the port is disabled so callers to
that port hear a busy signal. A number of occurrences can
temporarily disable a port, such as a power loss or when the
Octel 50 system shuts down after daily maintenance.
When/How to Use
It is generally recommended that you enable this parameter
so callers hear a busy signal instead of ringing when they
call a disabled port.
Some switches, such as those using digital integration, lock
the disabled ports when they have been off hook for a long
time. If your switch uses digital integration, you should
disable OFFHDIS. See the Configuration Note for your
switch for information on setting this parameter.
Related Parameters/Features
None.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
Yes
Requires
Restart
Yes
Switch-
Dependent
Yes
Set by
Integrator
No
Channel Specific Parameters - #175
Maximum Call
Duration
(PROGTIME)
This parameter specifies the maximum amount of time, in
minutes, the Octel 50 system allows a call to occupy a port
before it disconnects the call without warning.
When/How to Use
Use caution when setting this parameter. If callers are
disconnected while performing mailbox functions, such as
listening to messages or creating mailboxes, data corruption
could occur. Set this parameter to disable it.
If you set PROGTIME to a value greater than 0, consider the
following:
•
Set PROGTIME to a value high enough so calls
delivering faxes and callers on hold are not
disconnected.
•
PROGTIME overrides Message Time on the Class
of Service dialog box. Set PROGTIME higher to
prevent callers from being disconnected while
recording messages. If this happens, data
corruption could occur.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...