Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-6
Min
–
Max
–
Default
No
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
General Parameters - #5
Minimum Length
of Password
This parameter specifies the minimum number of digits the
Octel 50 system requires for a valid mailbox password. This
parameter is used as a security feature to require
subscribers to use passwords to log into their mailboxes.
When/How to Use
For most Octel 50 systems, the default should be sufficient.
If you change this parameter to a higher value, the Octel 50
system prompts subscribers using existing mailboxes to
change their passwords to comply with the new value before
gaining access to their mailboxes.
If you change this parameter to a lower value, subscribers
are not required to change their passwords, since their
current passwords exceed the minimum.
Related Parameters/Features
None.
If Set Too High
Subscribers are required to enter very long strings of
keypresses to access their mailboxes.
If Set Too Low
Setting this parameter low increases the chance that a
caller could guess a password and gain unauthorized
access to the Octel 50 system.
If this parameter is set to 0, a password is not required to
access system mailboxes. However, subscribers can assign
passwords to their mailboxes.
Min
0
Max
9
Default
4
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
General Parameters - #6
Daily
Maintenance
Time
This parameter determines when the Octel 50 system
performs its daily maintenance. During daily maintenance,
the Octel 50 system ages messages and purges expired
messages, updates statistics, and performs other functions.
Daily maintenance only takes a moment. The Octel 50
system remains up and continues to answer calls.
When/How to Use
Set this parameter to the desired hour in Military format, 0 to
23, where 0 represents midnight. This parameter can only
be set for the top of the hour and cannot be specified in
minutes.
Related Parameters/Features
If you enable Shutdown After Daily Maintenance, you should
set Daily Maintenance Hour for a low-traffic time so that call
traffic is not interrupted.
If Set Too High
Not applicable.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...