Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-48
Intercom Paging Parameters - #91
Paging Wait
Time (Intercom
Redirect)
This parameter specifies the number of seconds the Octel
50 system waits for a subscriber to respond to a page
before prompting the caller try another extension, leave a
message, page the subscriber, or disconnect. Note that the
Octel 50 system prompts callers to try the page again only if
Max. Number of Retries in Paging (Intercom Redirect) is set
greater than 0.
When/How to Use
For most Octel 50 systems the default should be sufficient.
However, if you find that many subscribers do not have
enough time to retrieve their pages, increase this
parameter.
Related Parameters/Features
This parameter specifies the time between the paging
retries specified in Max. Number of Retries in Paging
(Intercom Redirect) and the time between the paging
phrases for Repeat Intercom Paging Phrase.
If Set Too High
Callers may have to wait on hold for an excessive amount of
time before the subscriber answers the page or the Octel 50
system prompts them to try another extension, leave a
message, page the subscriber again (if Max. Number of
Retries in Paging (Intercom Redirect) is set greater than 0),
or disconnect.
If Set Too Low
Subscribers do not have adequate time to respond to a
page.
Min
10
Max
99
Default
30
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Call Transfer Parameters
The Call Transfer parameters define the general transfer and release code sequences
and dialing standards that enable the voice boards installed in the Octel 50 system to
communicate with the switch.
The minimums and maximums for the codes on this screen refer to the length of the entry
allowed, not an actual number.
Call Transfer Parameters - #92
Transfer Prefix
Code
This parameter defines the code required by the switch to
perform a transfer. The Octel 50 system places this code in
the command string that the voice board uses to signal the
switch to perform a transfer. This code is not used on most
switches.
This code is always placed before the extension in the
command string.
When/How to Use
This code is either hard-coded or programmable, depending
on the switch. It is recommended that you do not change
this parameter without speaking to a technical support
representative. If you do choose to modify this parameter,
write down the original code should you need to reenter it.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual value.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...