Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-89
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
15
Default
Blank
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Hangup Detection Parameters - #167
Hangup String
Timeout
(HANGUPDLY)
This parameter specifies the amount of time, in 100
millisecond units, that the Octel 50 system waits between
digits before identifying a string of DTMFs as a hangup
string. This eliminates false hangup string detections.
When/How to Use
This parameter is set when the Integrator utility is run.
Adjust this parameter only when instructed to by a technical
support representative.
Related Parameters/Features
This parameter must be set to a value greater than 0 if using
the Hangup String (HANGUPSTR) parameter.
If Set Too High
DTMFs from keypresses entered by callers or subscribers
using Octel 50 system features may be incorrectly
interpreted as hangup strings.
If Set Too Low
Hangup strings may be ignored if the switch cannot send
the digits fast enough to meet this value. This may cause
excessive off hook times between calls.
Min
0
Max
30000
Default
0
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Hangup Detection Parameters - #168
Minimum
Duration for
Drop in Loop
Current
(LCDTIME)
This parameter specifies the amount of time, in 10
millisecond units, necessary to recognize a drop in loop
current, when detecting a disconnect.
When/How to Use
This parameter is set when the Integrator utility is run.
Adjust this parameter only when instructed to by a technical
support representative.
A setting of 0 disables this parameter.
Related Parameters/Features
None.
If Set Too High
If the switch sends a loop current drop for a shorter time
than the time set for LCDTIME, the Octel 50 system does
not identify the disconnect. This may cause excessive off
hook times between calls.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...