Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-67
Message Waiting Light Parameters - #124
Light Message
Waiting Light for
Every Message
This parameter determines whether the Octel 50 system
sends a message waiting light request every time a
message is received.
When/How to Use
This parameter is set when the Integrator is run for switches
that do not reliably schedule message waiting lights. Do not
change the setting of this parameter unless instructed to by
a technical support representative.
The Octel 50 system synchronizes message waiting light
events by sending one message waiting light activation
code to a port, then one message waiting light deactivation
code when the messages are retrieved by the subscriber. If
this parameter is enabled, message waiting light
synchronization is disrupted when a port has several
message waiting light activation codes for a mailbox, and
receives only one message waiting light deactivation code.
When this occurs, the remaining message waiting light stay
active, even though there are no more new messages, until
the port is manually reset.
Some switches limit the number of message indications per
phone. In this case, do not enable this parameter.
Related Parameters/Features
If this parameter is enabled, outbound ports that activate
and deactivate message waiting lights are tied up until the
port is manually reset.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
No
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Message Waiting Light Parameters - #125
Message Waiting
Light Dials
Number On Hook
This parameter determines whether the phone system
remains on hook when the Octel 50 system sends the string
for message waiting light events.
When/How to Use
This parameter is set when the Integrator utility is run for
Octel 50 systems using some SL-1 integrations. Do not
adjust this parameter unless instructed to by a technical
support representative.
Related Parameters/Features
None.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
No
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...