Testing and Troubleshooting the Octel 50 System
Using the Octel 50 System Troubleshooting Table
O
CTEL
50 I
NSTALLATION
G
UIDE
13-30
•
Note that subscribers must check message confirmations
through the check message confirmations feature selected from
the Main menu. Confirmations are not sent as separate
messages.
•
Note that messages dispatched to remote sites using AMIS
cannot be sent with message confirmation activated.
Message delivery does not
work for a phone
Resolution Possibilities:
•
Attach a digit grabber to monitor a line. Verify the Octel 50
system can access the line and connect to the phone number.
•
If Debug displays the error “WARNING 18 No Dial tone
Detected,” all outbound ports were busy when notification was
attempted. You may want to enable more outbound ports on the
system.
System Setup parameters:
•
Verify at least one port is enabled for outbound events under
Channel Specific.
•
Verify that the Code for Accessing an Outside Line (for example
9,) is specified. If message delivery is to an internal extension
(less than the Number of Digits in Local Telephone Number), the
switch may require a Custom Message Delivery code.
•
Verify the value entered for DTONDET under Hangup Detection
is at least 400 units higher than the value entered for
DTONWAIT under Message Delivery.
•
The value for DTONDET may be set too low. If it is, the system
may hang up prematurely. Adjust this parameter only if
instructed to by a technical support representative.
Mailbox Entry dialog box:
•
Verify the Message Delivery feature is enabled on the
Subscriber Settings dialog box.
•
Verify the time blocks are configured on the Message Delivery
dialog box.
•
Verify the Message Delivery dialog box indicates PHONE in the
Call Back field.
Class of Service dialog box:
•
Verify the Message Delivery option is enabled.
•
Verify the Long Distance option under Message Delivery is
selected if subscribers are allowed to enter long distance
numbers for message delivery.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...