Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-71
Related Parameters/Features
If the Total Number of DID Digits is set to 0, this parameter
is not used.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
-1
Max
99
Default
0
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Inband Signaling Parameters - #132
Number of
Milliseconds to
Wait for Digits
This parameter defines the delay, in millisecond units,
between inband signaling tones sent from the switch. If the
Octel 50 system does not detect another tone within this
time, it processes the string. Each time the Octel 50 system
detects another tone, it resets the count for this parameter.
When/How to Use
This parameter is set when the Integrator utility is run. You
should not need to change it.
Related Parameters/Features
If the Total Number of DID Digits is set to 0, this parameter
is not used.
If no DID Terminating Character is defined, this parameter
determines when the Octel 50 system considers the string
to be complete.
If Set Too High
Setting this parameter higher may cause initial callers into
the system to hear silence before the main greeting is
voiced. Do not modify this parameter without talking to a
technical support representative.
If Set Too Low
The Octel 50 system may not receive the entire string.
Min
0
Max
9999
Default
0
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Inband Code for Go to Voice Mail
The Inband Code for Go to Voice Mail parameters configure the Octel 50 system to
transfer callers to subscriber mailboxes.
When the Integrator utility is run, the Octel 50 system enters default settings for the codes
required by the switch. These settings are determined based on default settings for the
switch. If you or the manufacturer modify the switch programming or features, integration
may be affected. If this occurs, call a technical support representative.
Inband Code for Go to Voice Mail Parameters - #133
Inband Code
String
This parameter specifies the code sent by the switch that
instructs the Octel 50 system to transfer the call directly to
the mailbox that follows the code.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...