Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-10
Min
–
Max
–
Default
No
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Receptionist Parameters - #12
Number
Attempts Rotary
Transfer to Busy
Operator
This parameter specifies the number of times the Octel 50
system attempts to transfer a rotary caller to the
receptionist’s extension when it is busy.
When/How to Use
The default should be sufficient for most Octel 50 systems.
If a call cannot be transferred to the receptionist, it is
directed to the receptionist’s mailbox and the caller can
leave a message.
This parameter only applies if calls to the receptionist are
supervised.
Related Parameters/Features
This parameter is not used if Disconnect All Rotary Callers
is enabled.
This parameter is not available if Enable Automated
Attendant is disabled.
If Set Too High
The higher you set this parameter, the longer the port
holding the rotary caller is tied up.
If Set Too Low
If this parameter is set to 0, the Octel 50 system attempts to
transfer rotary callers once before they are transferred to
voice mail to leave a message.
Min
0
Max
9
Default
3
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Receptionist Parameters - #13
Enable
Receptionist
Grunt Detection
This parameter determines whether callers may use short
words such as Yes to transfer to a receptionist.
When/How to Use
This parameter is useful for callers with rotary phones who
cannot successfully access the system but want to be
transferred to an operator. Also, this is useful for detecting
whether a caller has hung up before transferring the call to
the operator.
It is recommended that you leave this parameter disabled.
Related Parameters/Features
None.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...