Testing and Troubleshooting the Octel 50 System
Octel 50 Installation Test Plan
O
CTEL
50 I
NSTALLATION
G
UIDE
13-5
Connect
Test:
Call into the Octel 50 system and dial a mailbox
number. Answer the extension when it rings.
Expected Outcome:
Verify the Channel Status display shows the status
Connected for the port.
If this test fails, see the “Call analysis does not work”
section of the Octel 50 Troubleshooting Table for
possible resolutions.
Integrated/Serial SMDI (Unsupervised)
This section tests serial integration to verify Octel 50
correctly recognizes ring-no-answer and busy conditions.
Blind Transfer
Test:
For a test mailbox, set the Maximum Rings field
on the Class of Service dialog box to 0.
Call the Octel 50 pilot number.
If the Octel 50 system is set up for automatic
station login, press <0> to go to the Attendant
menu.
At the Attendant menu prompt, dial the mailbox
number.
Expected Outcome:
The Channel Status display should show the following
messages:
Transfer <mailbox number>
Dialing <extension number>
Waiting for Ring (or Data, or DID, depending on
integration)
Note that if station set forwarding is on, the call will be
returned to the Octel 50 system in a busy or no answer
situation.
If this test fails, see the “SMDI integration does not
work” section of the Octel 50 Troubleshooting Table for
possible resolutions.
Ring-No-Answer
Test:
Set the phone to forward to the Octel 50 system
in ring and no answer conditions.
In a test mailbox, set the No Answer/Call
Blocking feature to Default on the Subscriber
Settings dialog box.
For the same mailbox, set the Maximum Rings
on the Class of Service dialog box to 0.
Call into the Octel 50 system and dial the
mailbox number.
Do not answer the extension.
Expected Outcome:
Verify the system voices
, “I’m sorry, there is no answer
at that extension.”
Verify the Channel Status display shows the status
Ring/No Answer for the port.
If this test fails, see the “SMDI integration does not
work” section of the Octel 50 Troubleshooting Table for
possible resolutions.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...