Testing and Troubleshooting the Octel 50 System
Using the Octel 50 System Troubleshooting Table
O
CTEL
50 I
NSTALLATION
G
UIDE
13-17
Callers are disconnected
Resolution Possibilities:
•
Verify the method the switch uses for a disconnect. Verify the
appropriate Octel 50 hangup detection parameters are
configured. For information on verifying a switch’s disconnect
signal, see the topic, Determining a Switch’s Disconnect Signal,”
later in this chapter.
•
Note under what conditions callers are being disconnected.
•
Verify call analysis was run and Octel 50 correctly interprets
signals from the switch. If call analysis was run and Octel 50 still
cannot correctly interpret signals from the switch, contact a
technical support representative for information on using
Advanced Call Analysis.
System Setup parameters:
•
Turn off all System Setup parameters that cause disconnects to
help determine if the problem is caused by the phone system or
Octel 50:
−
Set Minimum Message Length in Seconds under
Message Timing to 0.
−
Increase Maximum Silence under Hangup Detection to
1200.
−
Set DTONDET under Hangup Detection to 0, if your
switch uses the BellCore tone table.
−
Set HANGUPDLY under Hangup Detection to 0.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...