Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-60
Dialing Parameters - #112
Code for
Accessing an
Outside Line
This parameter defines the code required by the switch to
access an outside line. This code is used by the Octel 50
system to obtain an outside line for outbound dialing
operations (message delivery, message waiting lights, and
wake-up calls) when the length of the destination phone
number equals or exceeds the Number of Digits in Local
Telephone Number. The Octel 50 system also uses this
code for AMIS network messaging when no AMIS Prefix or
Prefix Code is defined, regardless of the length of the
destination phone number.
‘
When/How to Use
This parameter is set when the Integrator utility is run, if
required by the switch.
This code consists of the number you normally press to dial
an outside line on the phone system, usually followed by a
comma to instruct the switch to wait momentarily before
dialing the number.
For most phone systems, the default 9, is used.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual number.
Related Parameters/Features
If the Code for Accessing an Outside Line is not properly
defined, the Octel 50 system will not be able to execute
outcalls.
The AMIS Prefix or Prefix Code parameters override the
Code for Accessing an Outside Line for AMIS outcalls.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
32
Default
9,
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Dialing Parameters - #113
Number of Digits
in Local
Telephone
Number
This parameter defines the number of digits in telephone
numbers in the local dialing area.
When/How to Use
In the United States and Canada, the default of 7 is normally
used. However, in other countries, the number of digits may
be different.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...