Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-68
Uninterruptable Power Supply Parameters
The Uninterruptable Power Supply parameters specify whether UPS integration is
enabled for the Octel 50 system and specifies the COM port to which the UPS is
connected.
Uninterruptable Power Supply Parameters - #126
Enable UPS
Integration
This parameter determines whether the Octel 50 system
can integrate with the UPS connected to the Octel 50 PC.
When/How to Use
If the Octel 50 system is integrated with the UPS, the Octel
50 system monitors the UPS status. If the power is
interrupted and the UPS battery is low, Octel 50 performs an
automatic shut down to prevent file corruption until the
power is restored.
Related Parameters/Features
The UPS COM Port parameter specifies the COM port to
which the UPS is connected, if this parameter is enabled.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
No
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Uninterruptable Power Supply Parameters - #127
UPS COM Port
This parameter specifies the COM port to which the UPS is
connected.
When/How to Use
Use this parameter when the Enable UPS Integration
parameter is enabled. Leave this parameter at the default,
0, if UPS integration is not supported.
Related Parameters/Features
The Enable UPS Integration parameter determines whether
UPS integration is supported on the Octel 50 system.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
4
Default
0
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Inband Signaling Parameters
The Inband Signaling parameters configure the Octel 50 system to properly receive and
interpret the inband information sent from the switch.
When the Integrator utility is run, the Octel 50 system enters default settings for the codes
required by the switch. These settings are determined based on default settings for the
switch. If you or the manufacturer modify the switch programming or features, integration
may be affected. If this occurs, call a technical support representative.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...