Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-94
Related Parameters/Features
If PROGTIME is shorter than the Message Time setting on
the Class of Service dialog box, callers may be
disconnected before they finish recording long messages.
If Set Too High
The higher you set this parameter, the longer callers are
allowed to remain in the Octel 50 system before being
disconnected.
If Set Too Low
Callers recording messages, sending faxes, or waiting in
call queues are disconnected without warning and data
corruption could occur. Set this parameter to 0 to disable it.
Min
0
Max
999
Default
30
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Channel Specific Parameters - #176
DTMF Length to
Interrupt a
Prompt
(PLAYDTMF)
This parameter specifies the length, in 10 millisecond units,
of a DTMF the voice board must receive to interrupt a
prompt voiced by the Octel 50 system.
When/How to Use
For most Octel 50 systems, the default value is sufficient. If
the Octel 50 system misinterprets voice data as DTMF
tones during prompts, try increasing this setting.
Related Parameters/Features
When RECDTMF is set to a higher value than PLAYDTMF,
the RECDTMF value is used for both.
If Set Too High
The Octel 50 system may not recognize DTMF tones and
does not interrupt the prompt.
If Set Too Low
The Octel 50 system may interpret voice data as DTMF.
Min
0
Max
30000
Default
0
Requires
Restart
Yes
Switch-
Dependent
Yes
Set by
Integrator
No
Channel Specific Parameters - #177
Printer LPT Port
(PRINTER)
This parameter indicates whether the system is using a
printer.
When/How to Use
The valid entries for this parameter are 1, 2, or N, where 1
or 2 corresponds to the LPT1 or LPT2 connection and N
corresponds to no printer.
Related Parameters/Features
None.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
1
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...