Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-84
Inband Code for No Answer Extension - #157
Total Length of
String
This parameter specifies the number of characters and
digits in the Code for No Answer Extension string.
When/How to Use
Calculate the Total Length of String by counting the number
of characters and digits that are sent in the Code for No
Answer Extension string. For example, if the code is $ and
the mailbox number is 1000, the string is $1000. In this
case, the Total Length of String is 5.
If this parameter is set to 0, the system does not test the
string length.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual number.
Related Parameters/Features
The length of the Inband Code String and the Number of
Digits in a Mailbox parameters determine the setting of the
Total Length of String parameter.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
99
Default
0
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
No
Inband Code for Go to Voice Mail and Get Mailbox
The Inband Code for Go to Voice Mail and Get Mailbox parameters configure the Octel 50
system to transfer callers to voice mail to request the mailbox number.
When the Integrator utility is run, the Octel 50 system enters default settings for the codes
required by the switch. These settings are determined based on default settings for the
switch. If you or the manufacturer modify the switch programming or features, integration
may be affected. If this occurs, call a technical support representative.
Inband Code for Go to Voice Mail and Get Mailbox - #158
Inband Code
String
This parameter specifies the code sent by the switch that
instructs the Octel 50 system to transfer a caller to voice
mail to retrieve the mailbox number.
When/How to Use
When this code is used, the caller hears,
“Please enter the
destination mailbox number.”
The Octel 50 system automatically sets this parameter when
the Integrator utility is run. You should not need to change
it.
Related Parameters/Features
The Location of Inband Signaling Code parameter specifies
where this code is located in an incoming inband string.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual number.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...