Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-87
Related Parameters/Features
The Location of Mailbox Number and the Start at the End of
String parameters work together. For example, if the
incoming string is 9*1123 and the mailbox number is 123,
the Number of DID Digits to use is 6, the DID Code is 9*1,
the Location of Inband Signaling Code is 1, and, if Start at
End of String is set to Yes, the Location of Mailbox Number
is 3. If Start at End of String is set to No, the Location of
Mailbox Number is set to 4.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
1
Max
99
Default
1
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Inband Code Default - #163
Start at End of
String
This parameter specifies whether the system starts at the
end of the default inband signaling string when counting
digits to locate the start of the mailbox number.
When/How to Use
Enable this parameter if variable-length strings are used.
Related Parameters/Features
The Location of Mailbox Number and the Start at the End of
String parameters work together. For example, if the
incoming string is 9*1123 and the mailbox number is 123,
the Number of DID Digits to use is 6, the DID Code is 9*1,
the Location of Inband Signaling Code is 1, and, if Start at
End of String is set to Yes, the Location of Mailbox Number
is 3. If Start at End of String is set to No, the Location of
Mailbox Number is set to 4.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
No
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Inband Code Default - #164
Off Hook Delay
Time (OFFHDLY)
This parameter determines the delay, in 10 millisecond
units, after the Octel 50 system takes a port off hook, before
it starts DIDTIME.
When/How to Use
This parameter is set when the Integrator utility is run. You
should not need to change it.
Related Parameters/Features
If the Total Number of DID Digits is set to 0, this parameter
is not available.
DIDTIME does not begin until OFFHDLY is reached.
If Set Too High
The Octel 50 system may regularly miss one or more inband
digits at the beginning of the string.
If Set Too Low
The Octel 50 system may prematurely drop incoming calls.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...