Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-45
Call Queuing Parameters - #85
Number of
Seconds for
First Caller in
Queue to Wait
This parameter specifies the number of seconds the Octel
50 system waits after attempting to transfer the first caller in
a queue to the desired extension before attempting to
transfer them again.
When/How to Use
For most Octel 50 systems, the default setting should be
sufficient. Increase this value if you want callers to remain
on hold longer between prompt voicing.
Related Parameters/Features
None.
If Set Too High
Callers may assume they have been disconnected and
hang up.
If Set Too Low
Not applicable; the default is the minimum allowed setting.
Min
1
Max
99
Default
1
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Intercom Paging Parameters
The Intercom Paging parameters define the codes the Octel 50 system dials to activate
the Intercom Paging feature. They also determine how many times and how often the
Octel 50 system pages a subscriber.
Intercom Paging Parameters - #86
Intercom Paging
Code
This parameter specifies the dialing string the Octel 50
system must send to the switch to activate Intercom Paging.
When the Octel 50 system initiates a page, it puts the caller
on hold, dials the Intercom Paging Code, then returns to the
caller.
When/How to Use
This parameter is set when the Integrator utility is run, if
required by the switch.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual value.
Related Parameters/Features
If you want to configure zone paging, enter the zone paging
code for each mailbox in the Number field under Intercom
Paging on the Subscriber Settings dialog box. This code
overrides the Intercom Paging code.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
15
Default
Blank
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...