Defining Phone System Signals
Running Call Progress Characterization (CPC) Call Analysis for Dialogic
Octel 50 Installation Guide
9-15
To run CPC, you must have access to one extension from the telephone switch. This
extension cannot be in a hunt or rollover group or in use by any other person during
the call analysis process. Additionally, the Auto Answer, Call Forwarding, and Camp-
On features must be deactivated during the test.
3. To test the on-hook signal, type
CPC -R10 -I(
IRQ#
)
at the \CVR prompt, then
press <ENTER>.
IRQ#
represents the hardware interrupt level set on the voice board.
4. When prompted, enter the available extension number. CPC dials the extension 10
times as it identifies the ring signal. The phone must be on hook at the extension.
When the process is complete, the \CVR prompt displays. If the phone continues to
ring, lift the receiver and hang it up again.
5. To test busy, verify that the extension is busy by creating a talk path to another
phone. Dialing another number ensures that there is not a tone change or time-out on
the line. From the \CVR prompt, type
CPC -B10 -I(
IRQ#
)
then press <ENTER>.
6. When prompted, enter the extension number. CPC dials the extension 10 times to
listen for a busy signal. During this process, you do not hear any sounds.
7. When the process is complete, hang up the receiver. The \CVR prompt displays.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...