Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-63
Min
0
Max
9
Default
1
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
No
Message Delivery Parameters - #117
Dial Tone
Timeout During
Message
Delivery
(DTONWAIT)
This parameter specifies the amount of continuous energy,
in 10 millisecond units, that the Octel 50 must detect from
the switch before recognizing it as dial tone. This parameter
helps to ensure that the Octel 50 system allows the switch
enough time to stabilize dial tone after completion of a call
before initiating an event.
This parameter only applies when the Octel 50 system goes
off hook to initiate an outbound message delivery or fax
event. The count for DTONWAIT starts as soon as a voice
port goes off hook.
If the Octel 50 system does not detect dial tone for the
specified time, the Octel 50 system assumes the port is
receiving an incoming call and attempts to answer.
When/How to Use
This parameter is set when the Integrator utility is run.
For most Octel 50 systems, the default value should be
sufficient to allow the switch to reset the port after a call
before the next event.
If you modify this parameter, make sure that it is less than
the value of DTONDET.
Related Parameters/Features
DTONDET must be set at least 4 seconds higher than
DTONWAIT. For example, if you set DTONWAIT to 300, set
DTONDET to at least 700.
If Set Too High
Switches send dial tone for a specified time before they time
out and stop sending it. If DTONWAIT is set too high, the
switch timeout is exceeded and DTONWAIT is never
completed. Consequently, the outbound event is never
initiated.
If Set Too Low
If DTONWAIT is set too low, and the switch does not send
constant, stable dial tone immediately, the Octel 50 system
attempts to answer the port, and the outbound event is
never initiated.
Min
0
Max
30000
Default
200
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...