Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-49
Related Parameters/Features
The Octel 50 system only looks for a Transfer Prefix Code if
no Custom Transfer Code is defined.
This parameter is not available when Enable Automated
Attendant is disabled.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
32
Default
Blank
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
No
Call Transfer Parameters - #93
Custom Transfer
Code
This parameter defines the series of commands required by
the switch to perform a transfer. The Octel 50 system uses
this code to instruct the switch to attempt a transfer for
switches that require something other than a standard hook
flash.
When/How to Use
This parameter is set when the Integrator utility is run, if
required by the switch.
This code is either hard-coded or programmable, depending
on the switch. It is recommended that you do not change
this parameter without speaking to a technical support
representative. If you do choose to modify this parameter,
write down the original code should you need to reenter it.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual value.
Custom Transfer Codes can include the following
commands and codes, which signal the switch to perform
specific actions:
&
Represents a flash hook
,
Represents a pause
−
Signals the switch to go on hook
+
Signals the switch to come off hook
D
Tells the switch to dial with call progress
H
Tells the switch to perform a hard hangup
N
Tells the switch to dial without call progress
R
Signals the switch to release the call to Octel 50
X
Places the extension in the dialing string
C
(Followed by a number) Indicates that the
system is to send a special feature code to the
switch. The C is always followed by a number
that defines how many characters are in the
special feature code. For example, if 550 is the
special feature code to activate intercom paging,
a C3 would be entered in the dialing code string
for intercom paging.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...