Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-17
sufficient.
When you set this parameter to 0, the message continues to
play without fast forwarding when subscribers use the Fast
Forward keypress.
Related Parameters/Features
None.
If Set Too High
When this parameter is set too high, subscribers do not
have much control over how much of the message they can
fast forward through when they use the Fast Forward
keypress.
If Set Too Low
When this parameter is set too low, subscribers must use
the Fast Forward keypress several times to fast forward the
desired portion of the message. Set this parameter to 0 to
disable it.
Min
0
Max
99
Default
5
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Message Timing Parameters - #26
Maximum Time to
Record Mailbox
Prompts
This parameter specifies the maximum amount of time, in
seconds, for subscribers to record mailbox prompts and
folder labels.
When/How to Use
For most Octel 50 systems, the default setting should be
sufficient.
Some applications may require longer prompts. For
example, using V-Trees, you may want to raise this
parameter value. Set this value lower if you need to limit the
amount of disk space to store prompts on small Octel 50
systems to conserve disk space.
Related Parameters/Features
None.
If Set Too High
The higher this setting, the more disk space mailbox
prompts and folder labels are allowed to use on Octel 50
systems.
If Set Too Low
The lower this setting, the less time subscribers have to
record their prompts and folder labels. If this parameter is
set to 0, subscribers cannot record prompts or folder labels.
Min
0
Max
999
Default
90
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Message Timing Parameters - #27
Minimum
Message Length
in Seconds
This parameter specifies the minimum length, in seconds, of
messages allowed on the Octel 50 system.
When/How to Use
For most Octel 50 systems using positive disconnect, the
default setting should be sufficient.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...