Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-7
If Set Too Low
Not applicable.
Min
0
Max
23
Default
0
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
General Parameters - #7
Shutdown
System After
Daily
Maintenance
This parameter determines whether the Octel 50 system
goes through an automatic shutdown after daily
maintenance is complete to run user-supplied backup
programs or other disk utilities. A batch file must be
designed to perform such functions. A sample Day of Week
batch file (DOW.BAT) is described in the Maintaining the
System section.
When/How to Use
Enable this parameter if you want to run third-party utilities
such as backups and disk maintenance after daily
maintenance.
Related Parameters/Features
The Daily Maintenance Time parameter setting determines
when the Octel 50 system will perform the shutdown.
If you enable Shutdown System After Daily Maintenance,
set the Daily Maintenance Time to a low-traffic time as the
Octel 50 system will be unable to accept calls until it
restarts.
When this parameter is enabled, the OFFHDIS parameter
determines whether callers hear a busy or no answer while
the Octel 50 system is shut down. Note that if OFFHDIS is
enabled, some phone switches may see the off hook as a
line problem and disable the ports.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
No
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Receptionist Parameters
The Receptionist parameters specify extensions where callers requesting to speak to a
receptionist or exceeding a specified number of errors are transferred during or after
business hours. These parameters also determine how the Octel 50 system handles
callers dialing from rotary phones and whether subscribers are informed of calls
transferred from the attendant.
Receptionist Parameters - #8
Default
Receptionist
Mailbox Number
This parameter defines the mailbox where the Octel 50
system routes callers during business hours when they
press <0> to speak to an operator, are dialing from a rotary
phone, or exceed the maximum number of errors allowed.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...