Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-23
When/How to Use
This parameter should be enabled for most Octel 50
systems. If you disable it, callers could become frustrated
having to call back to leave additional messages.
An application for which you may want to disable this
parameter is a service bureau, where you want callers
directly routed to subscriber mailboxes to leave a message
and then disconnected. Also, on smaller Octel 50 systems,
such as those with fewer ports, you may want to restrict
callers from tying up ports for considerable lengths of time.
Related Parameters/Features
If you enable this parameter, you can use the PROGTIME
parameter under Channel Specific Parameters to control the
total length of calls to the system.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
Yes
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Caller Parameters - #37
Permit Callers
Access to
Directory
Services
This parameter determines whether outside callers can
access subscriber directories.
If you enable this parameter, callers can press <*> to
access a directory they can use to dial the names of the
subscribers they want to reach.
If you disable this parameter, callers must know the number
of the subscribers they wish to speak to, or they can transfer
to the default operator.
When/How to Use
If the Octel 50 system is being used as a service bureau,
you may want to disable this parameter.
If you do not have a live operator, it is recommended that
this parameter be enabled. Otherwise, callers will have no
timely way of reaching subscribers whose numbers they do
not know.
Related Parameters/Features
To create directory entries, you must enter the First and
Last Names on the Mailbox Entry dialog box, and the
subscribers must record their name prompt.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
Yes
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
AMIS Parameters
The AMIS parameters identify the local Octel 50 system and define system-wide defaults
for dispatching network messages. Some of these parameters can be overridden on a
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...