Testing and Troubleshooting the Octel 50 System
Using the Octel 50 System Troubleshooting Table
O
CTEL
50 I
NSTALLATION
G
UIDE
13-23
transfers
•
Clear the previous CCA results and run Call Analysis again. For
more information on running Call Analysis, see the topic,
“Running Call Analysis,” in Chapter 9, Defining Phone System
Signals.”
Distribution lists do not work
Group distribution lists do not
work
Resolution Possibilities:
•
Verify the Distribution List option on the Class of Service dialog
box is enabled. The distribution lists feature provides access to
lists *0 through *9, which can be created by the mailbox owner
for that individual mailbox.
•
Verify a distribution list is created.
Global distribution lists do not
work
Resolution Possibilities:
•
Verify the Global Distribution option on the Class of Service
dialog box is enabled. This feature provides access to system
distribution lists *10 through *19, which can be created by a
system manager, and division-wide and company-wide lists (*98
and *99 respectively), which are automatically created by the
system.
•
Note that system distribution lists (*10-*19) can only be created
using the supervisor’s main menu available through the phone
interface.
•
Note that there must be more than one mailbox with entries in
the Company and Division fields on the Mailbox Entry dialog box
to create company-wide and division-wide distribution lists (*98
and *99).
•
Verify a system distribution list is created.
DTMFs are not recognized
properly
Resolution Possibilities:
System Setup parameters:
•
Verify the PLAYDTMF parameter under Voice System is set to
5.
•
If the system experiences talkoff (when a recording session is
interrupted by the system voicing prompts), increase the
RECDTMF parameter setting under Voice System. Verify
RECDTMF is set not higher than 7 or 8.
•
Verify the TONEDLY parameter under Call Transfer is set high
enough for the system to distinguish the time between DTMFs. If
this parameter is set to 8 and DTMFs still are not recognized,
contact a technical support representative.
•
Verify the TONELEN parameter under Call Transfer is high
enough so the system can distinguish DTMFs. If this parameter
is set to 8 and DTMFs still are not recognized, contact a
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...