Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-25
When/How to Use
Use the AMIS Prefix to identify the code that must be dialed
if you are part of a local network. For example, some
companies have multiple sites that use a code other than
the Code for Accessing an Outside Line to indicate that they
are dialing another network site.
If the customer’s system does not require a special prefix to
be dialed for network messages, leave this parameter blank.
The AMIS Prefix is not used for replies to network
messages; the Code for Accessing an Outside Line is used
instead.
If you need to use multiple prefixes, use the AMIS Prefix to
define the code used most often and then use the Prefix
Code field on the AMIS Node Entry dialog box to override
the AMIS Prefix for nodes that require a different prefix.
If you do not define an AMIS Prefix, subscribers sending
Casual AMIS messages to destinations that require a prefix
must insert the prefix before the destination telephone
number when dialing.
Related Parameters/Features
The Prefix Code field on the AMIS Node Entry dialog box
overrides the AMIS Prefix on a per-node basis.
The Octel 50 system uses the Code for Accessing an
Outside Line when no AMIS Prefix or Prefix Code is defined.
If you do not want to use a prefix or the Code for Accessing
an Outside Line, insert a comma in this field.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
3
Default
Blank
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
AMIS Parameters - #40
International
Access Code
This parameter defines the code used to access
international dialing in the country the Octel 50 system is
located. The Octel 50 system uses this code when sending
network replies to remote systems in other countries.
The Octel 50 system determines whether the International
Access Code is required for a reply by comparing the
Country Code of the remote destination to the Octel 50
system’s Country Code. If the codes are different, the Octel
50 system inserts the International Access Code in the
dialing string.
When/How to Use
Enter the International Access Code for the country in which
the local Octel 50 system is located. This code should only
contain numbers or commas.
The International Access Code for the United States is 011.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...