Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-82
Inband Code for Busy Extension - #153
Total Length of
String
This parameter specifies the number of characters and
digits in the Code for Busy Extension string.
When/How to Use
Calculate the Total Length of String by counting the number
of characters and digits that are sent in the Code for Busy
Extension string. For example, if the code is $ and the
mailbox number is 1000, the string is $1000. In this case,
the Total Length of String is 5.
If this parameter is set to 0, the system does not test the
string length.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual number.
Related Parameters/Features
The length of the Inband Code String and the Number of
Digits in a Mailbox parameters determine the setting of the
Total Length of String parameter.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
99
Default
0
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
No
Inband Code for No Answer Extension
The Inband Code for No Answer Extension parameters configure the Octel 50 system to
properly receive and interpret the inband information sent from the switch for extensions
that are not answered.
When the Integrator utility is run, the Octel 50 system enters default settings for the codes
required by the switch. These settings are determined based on default settings for the
switch. If you or the manufacturer modify the switch programming or features, integration
may be affected. If this occurs, call a technical support representative.
Inband Code for No Answer Extension - #154
Inband Code
String
This parameter specifies the code sent by the switch that
instructs the Octel 50 system to instruct the system that the
requested extension is not answered.
When/How to Use
When this code is used, the system routes the call
according to the mailbox’s call handling settings.
The Octel 50 system automatically sets this parameter when
the Integrator utility is run. You should not need to change
it.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual number.
Related Parameters/Features
The Location of Inband Signaling Code parameter specifies
where this code is located in an incoming inband string.
If Set Too High
Not applicable.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...