Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-98
When/How to Use
To return to the screen image, press any key. A setting of
99 disables this parameter.
Related Parameters/Features
None.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
1
Max
99
Default
5
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
PC Configuration Parameters - #186
Number of Calls
Between
Checkpoint File
Updates
(CKPRATE)
This parameter specifies the number of completed calls to
or from the Octel 50 system before the Checkpoint file,
OPERATOR.CKP, is saved. The Checkpoint file records
critical Octel 50 system data such as business hours,
statistics, system manager passwords, prompt assignments,
multilingual information, and group lists.
When/How to Use
This parameter should be set lower on lower call volume
systems than on high call volume systems. Do not set this
parameter to 0 as this disables it.
Related Parameters/Features
None.
If Set Too High
The higher you set this parameter, the longer between file
saves, and the greater the chance of data loss should there
be a power outage.
If Set Too Low
A low setting for this parameter does not affect system
performance. However, setting it to 0, which disables the
parameter, is not recommended.
Min
0
Max
99
Default
5
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
PC Configuration Parameters - #187
Rate to Poll the
Voice Driver
(EVENTRATE)
This parameter specifies the number of cycles between
checking for keystrokes. A cycle consists of scanning all
voice channels.
When/How to Use
The default should be acceptable for most Octel 50
systems. You should not modify this parameter unless
instructed to by a technical support representative.
Related Parameters/Features
None.
If Set Too High
There may be a delay in recognizing keystrokes.
If Set Too Low
On a small system, setting this too low may slow down the
system slightly.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...