Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-40
Fax Extensions
The Fax Extensions parameters are used for Octel 50 systems using the Transfer Method
to send and receive faxes. The Transfer Method is used when the Octel 50 system has
fewer fax ports than voice ports. When the Transfer Method is used, the Octel 50 system
must put the voice channel on hold, then dial a fax port extension.
Fax Extensions Parameters - #65
Transfer to
Extensions
(Requires
Shutdown)
This parameter determines whether the Octel 50 system
transfers calls from a voice port to a fax port when sending
and receiving faxes.
When/How to Use
Enable this parameter if the Octel 50 system must use the
Transfer Method to send and receive faxes.
If you enable this parameter, you must shutdown the Octel
50 system and then restart it for the change to be
recognized.
Related Parameters/Features
When Transfer to Extensions is enabled, you must
configure the Extension Connected to Fax Channel
n
parameters.
The Fax Extensions parameters are not available when the
Fax Board Type parameter is set to 0.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
No
Requires
Restart
Yes
Switch-
Dependent
No
Set by
Integrator
No
Fax Extensions Parameters - #66-77
Extension
Connected to
Fax Channel 0-11
These parameters define the phone system extension
number connected to each fax channel. Octel 50 systems
using the Transfer Method dial these extensions to transfer
faxes to a fax port.
When/How to Use
Enter the extension number for each fax port on your
system. The extensions you enter for each channel must be
valid extensions that you assigned to the fax ports. Note that
the channel numbers begin at 0. For example, if you have
four fax ports on the Octel 50 system, enter an extension for
ports numbered 0-3.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual number.
Related Parameters/Features
Transfer to Extensions (Requires Shutdown) must be
enabled for these parameters to be available.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...