Testing and Troubleshooting the Octel 50 System
Displaying Features Enabled on the Sentinel
O
CTEL
50 I
NSTALLATION
G
UIDE
13-41
Displaying Features Enabled on the Sentinel
An improperly programmed sentinel can inhibit the functionality of certain system
features. To confirm the sentinel is programmed appropriately, you can use the View
Sentinel program to display a list of enabled features.
To display features enabled on the sentinel:
1. If the Octel 50 system is not running, proceed to step 2. If the Octel 50 system is
running, shut down it down:
a. If the Mailbox Status screen is open and the Exit button is highlighted, press
<ENTER>. The Mailbox Status screen closes and the menu bar is activated with
the File menu highlighted.
b. Press <Alt-F> to view the File menu options.
c. From the File menu, use the down arrow key to select Exit then press <ENTER>.
The Shutdown System dialog box displays.
d. Select Shutdown then press <ENTER>. The system shutdown completes and the
\CVR prompt displays.
2. From the \CVR prompt, type
VIEWSENT
then press <ENTER>.
3. The sentinel information displays.
Interpreting the View Sentinel Information
The following information displays when you run the View Sentinel program:
•
Serial Number–Identifies the sentinel unit’s serial number. You may be asked to
provide this number when you contact a technical support representative.
•
Product Code–Indicates the product the sentinel is programmed to run.
•
Max Ports–Indicates the maximum number of channels the Octel 50 system is
allowed to use.
•
Max Mailboxes–Indicates the maximum number of mailboxes allowed on the
Octel 50 system.
•
Revision–Identifies the software version number the sentinel is programmed to
use.
•
Max Languages–Identifies the maximum number of languages allowed on the
Octel 50 system.
•
Fax Retrieval–Indicates whether the fax retrieval feature is enabled.
•
Fax Mail–Indicates whether the fax mail feature is enabled.
•
SMDI–Indicates whether SMDI Integration is allowed on the Octel 50 system.
•
AMIS–Indicates whether the AMIS analog protocol for networking is enabled.
•
Intercom Redirect–Indicates whether the intercom redirect feature is enabled.
•
Octel Board Required–Indicates whether Octel 50 must use voice and fax
boards with the proper signature. On indicates that a signatured board is required.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...