Call Transfer Parameters - #100
Inter-Digit Delay
Time (TONEDLY)
This parameter defines the delay, in 10 millisecond units,
between characters such as digits and commas in a dialing
string necessary for the switch to recognize them. This
parameter only applies to transfers or outcalls.
When/How to Use
If this parameter is blank, the Octel 50 system default of 5 is
used. This default should be sufficient for most switches.
Related Parameters/Features
Not applicable.
If Set Too High
The switch may fail to recognize DTMF.
If Set Too Low
The switch may not recognize the pause.
Min
0
Max
30000
Default
5
Requires
Restart
Yes
Switch-
Dependent
No
Set by
Integrator
No
Call Transfer Parameters - #101
Duration Time of
Valid DTMF
(TONELEN)
This parameter defines the minimum duration, in 10
millisecond units, of DTMF digits for them to be recognized
by the switch. This parameter only applies to transfer and
outcalls.
The TONELEN required for the switch is automatically
entered when the Integrator utility is run.
Related Parameters/Features
Not applicable.
If Set Too High
Setting this parameter higher should not adversely affect
Octel 50 system operation.
If Set Too Low
The switch may not recognize the digits.
Min
0
Max
30000
Default
10
Requires
Restart
Yes
Switch-
Dependent
Yes
Set by
Integrator
Yes
Call Transfer Parameters - #102
Enable Call
Progress
(CALLPROG)
This parameter specifies whether the system should dial the
number without listening for a busy/no answer/connect
signal.
If this parameter is enabled, the system places all outgoing
calls and transfers to a number or extension and listens for
a busy/no answer/connect signal. If this parameter is
disabled, the system does not listen for these signals, and
performs a blind transfer on all calls. A blind transfer may be
appropriate when calls are being transferred to another
application, such as Automatic Call Distribution (ACD),
instead of an extension.
Related Parameters/Features
If Enable Call Progress (CALLPROG) is disabled, the Inform
Subscriber Transfer is from Attendant and Start Delay for
Call Progress (STARTDLY) parameters are not used and
call queuing is not available.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...