Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-5
Related Parameters/Features
None.
If Set Too High
While you want to make sure that you allow mailboxes for
expansion, setting this parameter too high may make it
more difficult for subscribers to remember their mailbox
numbers.
If you set this parameter higher than the number of digits in
extension numbers on the phone system, inband signaling
may fail due to the mismatch between the length of the
extension and mailbox numbers.
If Set Too Low
You may not have enough mailboxes for the number of
subscribers and applications requiring one.
Min
1
Max
9
Default
4
Requires
Restart
–
Switch-
Dependent
No
Set by
Integrator
No
General Parameters - #3
Number of
Languages
This parameter specifies the number of languages installed
on the Octel 50 system.
When/How to Use
Enter the number of languages to use with the system. If
you are using multiple languages on the system, you must
load the appropriate voice files onto the system.
Related Parameters/Features
You must define the multilingual prompts on the System
Prompts dialog box and/or select an alternative language in
each mailbox’s class of service.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
1
Max
5
Default
1
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
General Parameters - #4
Tutor for New
Mailboxes
This parameter determines whether Co-Educator, the Octel
50 system tutorial, is enabled for subscribers accessing
their mailboxes for the first time.
Co-Educator provides an introduction to the Octel 50 system
and guides subscribers through the steps to change their
password and record their personalized prompts (Please
Hold, Directory, Name, and Personal Greeting prompts).
When/How to Use
Enable this parameter to help ensure that subscribers
change their password from the assigned default and record
their personalized prompts right away.
Related Parameters/Features
None.
If Set Too High
Not applicable.
Содержание Octel 50
Страница 2: ......
Страница 3: ...Octel 50 Installation Guide 585 313 134 Comcode 108503004 101 1840 000 Issue 1 June 1999 ...
Страница 8: ......
Страница 22: ...Determining System Needs Step 3 Consider Additional Hardware Needs OCTEL 50 INSTALLATION GUIDE 2 6 Notes ...
Страница 36: ...Installing the Hardware Step 10 Installing the Sentinel Octel 50 Installation Guide 3 14 Notes ...
Страница 52: ...Running the SMDI Utility Running SMDI as a Standalone Utility Octel 50 Installation Guide 5 4 Notes ...
Страница 180: ...Integrating with an Uninterruptible Power Supply Running UPS Integration Octel 50 Installation Guide 10 4 Notes ...