Parameter
Special operation
FR-E700 SC EC/ENE
6 - 311
Dancer roller position detection signal adjustment
When terminal 4 input is voltage input, 0 V is minimum position and 5 V (10 V) is maximum position.
When current is input, 4 mA is minimum position and 20 mA is maximum position (initial value). When
0 to 7 V is output from the potentiometer, it is necessary to calibrate C7 (Pr. 905) at 7 V.
햲
After changing the current/voltage input switch to "V", set "2" in Pr. 267 to change terminal 4 input
to voltage input.
햳
Input 0 V to across terminal 4 and 5 to calibrate C6 (Pr. 904). (% display displayed at analog
calibration is irrelevant to % of the feed back value.)
햴
By inputting 7 V to across terminal 4 to 5, calibrate C7 (Pr. 905). (% display displayed at analog
calibration is irrelevant to % of the feed back value.)
햵
Set 50% in Pr. 133.
쑶
I001843E
Fig. 6-161:
Dancer roller position detection signal adjustment
Example
쑴
Control at a dancer center position using a 0 to 7 V potentiometer
NOTE
When the Pr. 267 setting was changed, check the voltage/current input switch setting. Different
setting may cause a fault, failure or malfunction. (Refer to page 6-178 for setting.)
Feedback value
Potentiometer, etc.
Lower limit
position
Upper limit
position
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......