Parameter
Frequency setting by analog input (terminal 2, 4)
FR-E700 SC EC/ENE
6 - 177
6.16
Frequency setting by analog input (terminal 2, 4)
6.16.1
Analog input selection (Pr. 73, Pr. 267)
You can select the function that switches between forward rotation and reverse rotation according to
the analog input terminal specifications and input signal.
The following settings are possible:
●
Select reference voltages and currents: 0–10 V, 0–5 V or 0/4–20 mA
●
Suppress motor reversing
The above parameters can be set when Pr. 160 "User group read selection" = 0.
Purpose
Parameters that must be set
Refer to
Section
Selection of voltage/current input
(terminal 2, 4)
Perform forward/reverse rotation by
analog input.
Analog input selection
Pr. 73, Pr. 267
Adjustment (calibration) of analog
input frequency and voltage (current)
Bias and gain of frequency setting voltage
(current)
Pr. 125, Pr. 126,
Pr. 241, C2–C7
(Pr. 902–Pr. 905)
Pr. No. Name
Initial Value
Setting
Range
Description
Parameters referred to
Refer to
Section
73
Analog input
selection
1
0
Terminal 2: 0–10 V
Without reversible operation
125
126
C2
–
C7
Terminal 2 frequency
setting gain frequency
Terminal 4 frequency
setting gain frequency
Terminal 2 frequency
setting bias frequency
to
Terminal 4 frequency
setting gain
1
Terminal 2: 0–5 V
10
Terminal 2: 0–10 V
With reversible operation
11
Terminal 2: 0–5 V
267
Terminal 4 input
selection
0
Voltage/Current Input Switch
Description
0
Terminal 4: 0/4–20 mA
1
Terminal 4: 0–5 V
2
Terminal 4: 0–10 V
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......