CC-Link IE Field Network Basic
Parameter
6 - 350
CC-Link extended setting (Pr. 544)
Use this parameter to select the function of the remote registers for the CC-Link IE Field Network Basic.
Frequency command with sign (Pr. 541)
●
The start command (forward/reverse rotation) can be inverted by adding a plus or minus sign to
the value of the frequency command sent through the CC-Link IE Field Network Basic.
●
The Pr. 541 "Frequency command sign selection setting" is applied to the frequency command
from RWw1. (Refer to page 6-358.)
●
Relationship between the start command and sign (Pr. 541="1")
Pr. 544
Description
Refer to page
0 (initial setting)
Compatible with CC-Link Ver.1
1
Compatible with CC-Link Ver.1
12
Compatible with the double setting of CC-Link Ver.2
14
Compatible with the quadruple setting of CC-Link Ver.2
18
Compatible with the octuple setting of CC-Link Ver.2
Tab. 6-141:
Settings of Pr. 544
Pr. 541
Sign
Setting range
Actual frequency command
0
Not used
0 to 40000
0 to 400.00 Hz
1
With
–32768 to 32767 (two's complement)
-327.68 to 327.67 Hz
Tab. 6-142:
Function of the sign selection with Pr. 541
Start command
Sign of the frequency command
Actual run command
Forward rotation
+
Forward rotation
–
Reverse rotation
Reverse rotation
+
Reverse rotation
–
Forward rotation
Tab. 6-143:
Influence of the sign on the rotation direction
NOTES
When Pr. 541 = 1 (with sign)
●
When E²PROM write is specified with the RYE, write mode error (error code H01) will occur.
●
When concurrent execution of both RYD and RYE is enabled (when a value other than 0 is set in
Pr. 544) and both RYD and RYE are turned on, RYD has precedence.
●
When power is turned on (inverter reset), the initial setting status of the sign bit is "positive"
and the set frequency is "0 Hz". (The motor does not operate at the frequency set before turn-
ing OFF the power (inverter reset).)
●
When set frequency is written with the instruction code of HED and HEE, the sign of the fre-
quency command is not changed.
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......