Parameter
Selection of operation mode and operation location
FR-E700 SC EC/ENE
6 - 219
Specify operation mode at power on (Pr. 340)
Depending on the Pr. 79 and Pr. 340 settings, the operation mode at power on (reset) changes as de-
scribed below:
햲
The operation mode cannot be switched directly between the PU operation mode and network
operation mode.
햳
Operation mode can be changed between the PU operation mode and network operation mode
with the PU/EXT key of the operation panel and X65 signal.
Pr. 340
Pr. 79
Operation Mode
at Power on, Power Restoration, Reset
Operation Mode Switching
0
(initial
value)
0
(initial
value)
External operation mode
Can be switched to external, PU or NET opera-
tion mode
햲
1
PU operation mode
Fixed to PU operation mode
2
External operation mode
Can be switched to external or NET operation
mode
Switching to PU operation mode disabled
3 / 4
External/PU combined operation mode
Operation mode switching disabled
6
External operation mode
Can be switched to external, PU or NET opera-
tion mode with operation continued
7
X12 (MRS) signal ON: External operation mode
Can be switched to external, PU or NET opera-
tion mode
햲
X12 (MRS) signal OFF: External operation
mode
Fixed to external operation mode (Forcibly
switched to external operation mode.)
1
0
NET operation mode
Same as when Pr. 340 = 0
1
PU operation mode
2
NET operation mode
3 / 4
External/PU combined operation mode
6
NET operation mode
7
X12 (MRS) signal ON: NET operation mode
X12 (MRS) signal OFF: External operation
mode
10
0
NET operation mode
Can be switched to PU or NET operation
mode
햳
1
PU operation mode
Same as when Pr. 340 = 0
2
NET operation mode
Fixed to NET operation mode
3 / 4
External/PU combined operation mode
Same as when Pr. 340 = 0
6
NET operation mode
Can be switched to PU or NET operation mode
with operation continued
햳
7
External operation mode
Same as when Pr. 340 = 0
Tab. 6-60:
Operation mode of the inverter at power on
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......