Parameter overview
Parameter
6 - 6
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter-
Copy
Para-
meter
Clear
All
Para-
meter
Clear
Refer
to
Page
Rela
te
d
Paramet
ers
✔
: Enabled
—: Disabled
Av
oid mechanical r
esonanc
e poin
ts
31
Frequency jump 1A
0.01 Hz
9999
0–400 Hz/
9999
1A to 1B, 2A to 2B, 3A to 3B are frequency
jumps
9999: Function invalid
✔
✔
✔
32
Frequency jump 1B
0.01 Hz
9999
0–400 Hz/
9999
✔
✔
✔
33
Frequency jump 2A
0.01 Hz
9999
0–400 Hz/
9999
✔
✔
✔
34
Frequency jump 2B
0.01 Hz
9999
0–400 Hz/
9999
✔
✔
✔
35
Frequency jump 3A
0.01 Hz
9999
0–400 Hz/
9999
✔
✔
✔
36
Frequency jump 3B
0.01 Hz
9999
0–400 Hz/
9999
✔
✔
✔
Speed displa
y and
speed setting
37
Speed display
0.001
0
0
Frequency display, setting
✔
✔
✔
0.01–9998
Set the machine speed at 60 Hz.
RUN k
ey r
ota
tion
dir
ec
tion selec
tion
40
RUN key rotation direction
selection
1
0
0
Forward rotation
✔
✔
✔
1
Reverse rotation
Det
ec
tion of output
frequenc
y (SU
, FU)
41
Up-to-frequency
sensitivity (SU output)
0.1%
10%
0–100%
Set the level where the SU signal turns on.
✔
✔
✔
42
Output frequency detection
(FU output)
0.01 Hz
6Hz
0–400 Hz
Set the frequency where the FU signal turns
on.
✔
✔
✔
43
Output frequency detection
for reverse rotation
0.01 Hz
9999
0–400 Hz
Set the frequency where the FU signal turns
on in reverse rotation.
✔
✔
✔
9999
Same as Pr. 42 setting
—
44
45
Refer to Pr. 7 and Pr. 8
46
Refer to Pr. 0
47
Refer to Pr. 3
48
Refer to Pr. 22
—
51
Refer to Pr. 9
Tab. 6-1:
Parameter overview (6)
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......