Selection of operation mode and operation location
Parameter
6 - 226
Selection of control source in network operation mode (Pr. 338, Pr. 339)
As control sources, there are the operation command source that controls the signals related to the
inverter start command and function selection and the speed command source that controls the sig-
nals related to frequency setting.
In network operation mode, the commands from the external terminals and communication (PU con-
nector or communication option) are as listed below.
Operation
Location
Selection
Communication Operation Command
Source (Pr. 338)
0: NET
1: External
Remarks
Communication Speed Command
Source (Pr. 339)
0: NET
1:
External
2:
External
0: NET
1:
External
2:
External
Fixed function
(Terminal-
equivalent
function)
Running frequency from communication
NET
—
NET
NET
—
NET
Terminal 2
—
Exter-
nal
—
—
Exter-
nal
—
Terminal 4
—
External
—
External
S
elec
tiv
e func
tion
P
r. 178 t
o P
r. 184 setting
0
RL
Low speed operation command/
remote setting clear/stop-on
contact selection 0
NET
External
NET
External
Pr. 59 = 0
(multi-speeds)
Pr. 59 = 1, 2 (remote)
Pr. 270 = 1
(stop-on-contact 0)
1
RM
Middle-speed operation
command/remote setting
deceleration
NET
External
NET
External
2
RH
High speed operation
command/remote setting
acceleration
NET
External
NET
External
3
RT
Second function selection/stop-
on contact selection 1
NET
External
Pr. 270 = 1
(stop-on-contact 1)
4
AU
Terminal 4 input selection
—
Combined
—
Combined
5
JOG
Jog operation selection
—
External
7
OH
External thermal relay input
External
8
REX
Fifteen speed selection
NET
External
NET
External
Pr. 59 = 0
(multi-speeds)
10
X10
Inverter operation enable signal
External
12
X12
PU operation external interlock
External
14
X14
PID control valid terminal
NET
External
NET
External
15
BRI
Brake opening completion signal
NET
NET
16
X16
PU-external operation
switchover
External
18
X18
V/F switching
NET
External
Tab. 6-64:
Writing operation and speed commands (1)
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......