Parameter
Monitor display and monitor output signals
FR-E700 SC EC/ENE
6 - 143
쑶
NOTES
By setting "0" in Pr. 52, the monitoring of output speed to alarm display can be selected in
sequence by the SET key.
When the operation panel is used, the displayed units are Hz and A only and the others are not
displayed.
The monitor set in Pr. 52 is displayed in the third monitor position. However, change the output
current monitor for the motor load factor.
The monitor displayed at powering on is the first monitor. Display the monitor to be displayed on
the first monitor and press the SET key for 1 s. (To return to the output frequency monitor, hold
down the SET key for 1 s after displaying the output frequency monitor.)
I001800E
Fig. 6-68:
Displaying various types of monitor
Example
쑴
When Pr. 52 is set to "20" (cumulative energizing time), the monitor is displayed on the operation
panel as described below.
I001801C
Fig. 6-69:
Selection of the third monitor
Power on monitor (first monitor)
Second monitor
Third monitor
Alarm monitor
Output frequency
Output current
Output voltage
With
fault
Power on monitor (first monitor) Second monitor
Third monitor
Alarm monitor
Output frequency
Output current
Cumulative energizing time
With
fault
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......