Parameter overview
Parameter
6 - 14
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter-
Copy
Para-
meter
Clear
All
Para-
meter
Clear
Refer
to
Page
Rela
te
d
Paramet
ers
✔
: Enabled
—: Disabled
Offline aut
o tuning
82
Motor excitation current
0.01 A *
9999
0–500 A *
Tuning data (The value measured by offline
auto tuning is automatically set.)
* The range differs according to the
Pr. 71 setting.
✔
—
✔
9999
Uses the Mitsubishi motor (SF-JR, SF-HRCA)
constants
83
Motor rated voltage
0.1 V
200 V/
400 V *
0–1000 V
Set the rated motor voltage (V).
* The initial value differs according to the
voltage class: 200 V/400 V
✔
✔
✔
84
Rated motor frequency
0.01 Hz
50 Hz
10–120 Hz
Set the rated motor frequency (Hz).
✔
✔
✔
90
Motor constant (R1)
0.001 *
9999
0–50 *
Tuning data (The value measured by offline
auto tuning is automatically set.)
* The range differs according to
the Pr. 71 setting.
✔
—
✔
9999
Use constants of the Mitsubishi motor
(SF-JR, SF-HR, SF-JRCA, SF-HRCA)
91
Motor constant (R2)
0.001 *
9999
0–50 *
Tuning data (The value measured by offline
auto tuning is automatically set.)
* The range differs according to
the Pr. 71 setting.
✔
—
✔
9999
Use constants of the Mitsubishi motor
(SF-JR, SF-HR, SF-JRCA, SF-HRCA)
92
Motor constant (L1)
0.1 mH *
9999
0–1000 mH *
Tuning data (The value measured by offline
auto tuning is automatically set.)
* The range differs according to
the Pr. 71 setting.
✔
—
✔
9999
Use constants of the Mitsubishi motor
(SF-JR, SF-HR, SF-JRCA, SF-HRCA)
93
Motor constant (L2)
0.1 mH *
9999
0–1000 mH *
Tuning data (The value measured by offline
auto tuning is automatically set.)
* The range differs according to
the Pr. 71 setting.
✔
—
✔
9999
Use constants of the Mitsubishi motor
(SF-JR, SF-HR, SF-JRCA, SF-HRCA)
Tab. 6-1:
Parameter overview (14)
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......