Parameter overview
Parameter
6 - 12
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter-
Copy
Para-
meter
Clear
All
Para-
meter
Clear
Refer
to
Page
Rela
te
d
Paramet
ers
✔
: Enabled
—: Disabled
Carrier fr
equenc
y and
Sof
t-PWM selec
tion
72
PWM frequency selection
1
1
0–15
PWM carrier frequency can be changed. The
setting displayed is in [kHz]. Note that 0
indicates 0.7 kHz, 15 indicates 14.5 kHz.
✔
✔
✔
240
Soft-PWM operation
selection
1
1
0
Soft-PWM invalid
✔
✔
✔
1
When Pr. 72 = "0 to 5", Soft-PWM is valid.
Analog input selec
tion
73
Analog input selection
1
1
Terminal 2 input
Polarity reversible
✔
—
✔
0
0–10 V
Not used
1
0–5 V
10
0–10 V
With
11
0–5 V
267
Terminal 4 input selection
1
0
0
Terminal 4 input 4 to 20 mA
✔
—
✔
1
Terminal 4 input 0 to 5 V
2
Terminal 4 input 0 to 10 V
Noise elimina
tion a
t
the analog input
74
Input filter time constant
1
1
0–8
The primary delay filter time constant for the
analog input can be set.
A larger setting results in a larger filter.
✔
✔
✔
Reset selec
tion/
disc
onnec
ted PU/PU st
op
75
Reset selection/
disconnected PU/PU stop
1
14
0–3/14–17
You can select the reset input acceptance,
disconnected PU (operation panel/FR-PU04/
FR-PU07) connector detection function and
PU stop function. For the initial value, reset
always enabled, without disconnected PU
detection, and with PU stop function are set.
✔
—
—
Pr
ev
en
tion of
par
amet
er r
ewrit
e
77
Parameter write selection
1
0
0
Write is enabled only during a stop
✔
✔
✔
1
Parameter write is disabled.
2
Parameter write is enabled in any operation
mode regardless of operation status.
Note:
Parameters that can generally be written
during operation should not be written as well
with this setting.
Pr
ev
en
tion of r
ev
erse
rota
tion of the mot
or
78
Reverse rotation prevention
selection
1
0
0
Both forward and reverse rotations allowed
✔
✔
✔
1
Reverse rotation disallowed
2
Forward rotation disallowed
Tab. 6-1:
Parameter overview (12)
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......