Parameter
Parameter overview
FR-E700 SC EC/ENE
6 - 19
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter-
Copy
Para-
meter
Clear
All
Para-
meter
Clear
Refer
to
Page
Rela
te
d
Paramet
ers
✔
: Enabled
—: Disabled
PID c
on
tr
ol
127
PID control automatic
switchover frequency
0.01 Hz
9999
0–400 Hz
Set the frequency at which the control is
automatically changed to PID control.
✔
✔
✔
9999
Without PID automatic switchover function
128
PID action selection
1
0
0
PID control invalid
✔
✔
✔
20
PID reverse action
Measured value input
(terminal 4)
Set value
(terminal 2 or Pr. 133)
21
PID forward action
40–43
Dancer control
50
PID reverse action
Deviation value signal
input
(CC-Link
communication)
51
PID forward action
60
PID reverse action
Measured value and set
point input
(CC-Link
communication)
61
PID forward action
129
PID proportional band
0.1%
100%
0.1–1000%
If the proportional band is narrow
(parameter setting is small), the
manipulated variable varies greatly with a
slight change of the measured value.
Hence, as the proportional band narrows,
the response sensitivity (gain) improves but
the stability deteriorates, e.g. hunting
occurs. Gain Kp = 1/proportional band
✔
✔
✔
9999
No proportional control.
130
PID integral time
0.1 s
1 s
0.1–360 0s
Time required for only the integral (I) action
to provide the same manipulated variable as
that for the proportional (P) action. As the
integral time decreases, the set point is
reached earlier but hunting occurs more
easily.
✔
✔
✔
9999
No integral control.
131
PID upper limit
0.1%
9999
0–100%
Set the upper limit value.
If the feedback value exceeds the setting, the
FUP signal is output. The maximum input
(20 mA/5 V/10 V) of the measured value
(terminal 4) is equivalent to 100%.
✔
✔
✔
9999
No function
132
PID lower limit
0.1%
9999
0–100%
Set the lower limit value.
If the process value falls below the setting
range, the FDN signal is output. The
maximum input (20 mA/5 V/10 V) of the
measured value (terminal 4) is equivalent to
100%
✔
✔
✔
9999
No function
133
PID action set point
0.01%
9999
0–100%
Used to set the set point for PID control in
the PU operation mode.
✔
✔
✔
9999
No function
134
PID differential time
0.01 s
9999
0.01–10.00 s
Time required for only the differential (D)
action to provide the same manipulated
variable as that for the proportional (P)
action. As the differential time increases,
greater response is made to a deviation
change.
✔
✔
✔
9999
No differential control.
Tab. 6-1:
Parameter overview (19)
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......