Parameter
Communication operation and setting
FR-E700 SC EC/ENE
6 - 287
Ethernet IP filtering function (Pr. 837 to Pr. 843)
Set the IP address range for connectable network devices (Pr. 837 to Pr 843) to limit the connectable
devices. The IP address setting range depends on the settings in Pr. 838 and Pr. 841, Pr. 839 and Pr. 842,
and Pr. 840 and Pr. 843. (Either of the settings can be larger than the other in Pr. 838 and Pr. 841, Pr. 839
and Pr. 842, and Pr. 840 and Pr. 843.)
쑶
쑶
●
When Pr. 837 to Pr. 840 = "0 (initial value)", the function is invalid.
●
When Pr. 841 to Pr. 843 = "9999 (initial value)", the range is invalid.
Example
쑴
Setting example 1:
In this case, the IP address range in which Ethernet communication is permitted is
"192.168.x (1 to 3).xxx (100 to 150)".
I003110A
Fig. 6-139:
Setting example 1 for Ethernet IP filtering function
Example
쑴
Setting example 2:
In this case, the IP address range in which Ethernet communication is permitted is
"192.168.2.xxx (50 to 100)".
I003111A
Fig. 6-140:
Setting example 2 for Ethernet IP filtering function
192
168
1
100
ʊ
9999
3
150
The range is between
the values set in both
parameters.
The range is between the
values set in both
parameters.
Ethernet IP address for
filtering
Filtering range setting for
the Ethernet IP address
Pr. 837
Pr. 838
Pr. 839
Pr. 840
Pr. 841
Pr. 842
Pr. 843
192
168
2
100
ʊ
9999
9999
50
The range is between the
values set in both
parameters
Ethernet IP address for
filtering
Filtering range setting for
the Ethernet IP address
Pr. 837
Pr. 838
Pr. 839
Pr. 840
Pr. 841
Pr. 842
Pr. 843
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......