Parameter
Parameter overview
FR-E700 SC EC/ENE
6 - 13
햲
These parameters are communication parameters that are not cleared when parameter clear (all
clear) is executed from RS-485 communication.
(Refer to section 6.19 for RS-485 communication).
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter-
Copy
Para-
meter
Clear
All
Para-
meter
Clear
Refer
to
Page
Rela
te
d
Paramet
ers
✔
: Enabled
—: Disabled
Oper
ation mode selec
tion
79
Operation mode selection
1
0
0
External/PU switch over mode
✔
✔
✔
1
Fixed to PU operation mode
2
Fixed to External operation mode
3
External/PU combined operation mode 1
4
External/PU combined operation mode 2
6
Switch-over mode
7
External operation mode
(PU operation interlock)
340
Communication start-up
mode selection
1
0
0
As set in Pr. 79.
✔
✔
햲
✔
햲
1
Started in the network operation mode.
10
Started in the network operation mode.
Operation mode can be changed between
the PU operation mode and network
operation mode from the operation panel.
Selec
tion of c
on
tr
ol method
80
Motor capacity
0.01 kW
9999
0.1–15 kW
Set the applied motor capacity.
✔
✔
✔
9999
V/F control is performed
81
Number of motor poles
1
9999
2/4/6/8/10
Set the number of motor poles.
✔
✔
✔
12/14/16/18/
20
X18 signal ON:
V/F control
Set 10 + number of
motor poles
9999
V/F control is performed
89
Speed control gain (advanced
magnetic flux vector)
0.1%
9999
0–200%
Motor speed fluctuation due to load
fluctuation is adjusted during advanced
magnetic flux vector control.
100% is a referenced value.
✔
—
✔
9999
Gain matching with the motor set in Pr. 71.
800
Control method selection
1
20
20
Advanced
magnetic flux
vector control
Set a value other than
"9999" in Pr. 80 and Pr.
81.
✔
✔
✔
30
General-purpose
magnetic flux
vector control
Tab. 6-1:
Parameter overview (13)
AD
MFVC
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC
GP
MFVC
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......