KBBC SERIES OPERATING INSTRUCTIONS

 

 
 

(A40140) – Rev. A00 – 6/10/2014 

Page 1 of 4 

FIGURE 1 

CONTROL LAYOUT AND GENERAL CONNECTION DIAGRAM 

P5

P1

Notes: 1.

 If Key Switch is not used, a connection must be made between the red wire of Connector P1 (Terminal 3) and quick-connect 

Terminal B+ for the control to operate. 

2.

 To reset the control in wig-wag mode, return the Main Speed Potentiometer to the center position.    

3.

 Run Forward and Run Reverse Switches are not used in wig-wag operation. 

4.

 If wiring a fuse or circuit breaker, it must be wired in the 

location shown, immediately after the battery positive (+) terminal. The Key Switch must be wired after the fuse or circuit breaker.    
 

FIGURE 2 

DESCRIPTION AND WIRING OF CONNECTORS 

Summary of Contents for KBBC Series

Page 1: ... a connection must be made between the red wire of Connector P1 Terminal 3 and quick connect Terminal B for the control to operate 2 To reset the control in wig wag mode return the Main Speed Potentiometer to the center position 3 Run Forward and Run Reverse Switches are not used in wig wag operation 4 If wiring a fuse or circuit breaker it must be wired in the location shown immediately after the...

Page 2: ...ed the DECEL Trimpot has no effect output will go to zero in 0 1 seconds Adjustment Range 0 1 15 Seconds Factory Setting 2 Seconds 2 ACCEL 0 1 15 Acceleration ACCEL Allows for controlled acceleration from zero to full speed Acceleration is active in any turn on condition including Enable Key Switch or release of inhibit Adjustment Range 0 1 15 Seconds Factory Setting 2 Seconds MIN 0 30 Minimum Spe...

Page 3: ...Limit J3 Non Timed Current Limit Timed Current Limit Disables or enables the shutdown of the control due to motor overcurrent after 7 seconds High Pedal Disable J4 Non High Pedal Disable High Pedal Disable In HPD the Main Speed Potentiometer needs to be reset to zero before motor is allowed to run Stop Mode J5 Decel Fixed Allows stop function Enable Key Switch Direction Command to use DECEL Trimpo...

Page 4: ... used to enable power to the control Power On LED will illuminate green to indicate that the Key Switch is activated 3 Main Speed Potentiometer 5 k Ohm 4 The mechanical life of the relay is 10 million cycles The Cycle Jumper J7 is useful for repetitive on off cycling of the control In the OFF position cycling off the relay will engage to brake when a stop command is given In the ON position cyclin...

Page 5: ...e year it is necessary to recondition the power supply bus capacitors To recondition the bus capacitors apply the DC input voltage with the drive in the Stop Mode for a minimum of one hour Not following this procedure will cause the bus capacitors to fail A40196 Rev A00 8 13 2013 ...